Network Sciences is your source for LEGACY and OBSOLETE crystal filters. Contact the factory at 602-258-8095 or your representative

Our 21.4 Series MHz Monolithic Crystal Filters


12.5 KHz CHANNEL SPACING

TYPE

POLE
NUMBER

PASS BAND
WIDTH

STOP BAND WIDTH

RIPPLE

dB

INSERTION
LOSS
dB
GUARANTEED
ATTENUATION
TERMINATING
IMPEDANCE
R1 //C1(W//pF)
OPERATING
TEMP.RANGE
0
c
CASE
dB kHz dB kHz dB kHz dB to ±kHz
21R08AZ 2 3 ±3.75 20 ±18 - - 0.5 1.5 35
50
+350~+1000
-200~ -1000
850//6 -20~+70 UM-1
21R08BZ 4 3 ±3.75 40 ±14 - - 1.0 2.5 65 +350~+1000
-200~ -1000
850//6 -20~+70 (UM-1)X2
21R08CZ 6 3 ±3.75 45 ±8.75 65 ±12.5 2.0 3.0 65 ±12.5~±300 850//6 -20~+70 S-1*R-1
21R08DZ 8 3 ±3.75 65 ±9.0 90 ±12.5 2.0 4.0 90 ±12.5~±300 850//6 -20~+70 S-2*R-2
21R08EZ 10 3 ±3.75 75 ±9.0 90 ±10.0 2.0 5.0 90 ±10.0~±300 850//6 -20~+70 S-3*R-3

25 KHz CHANNEL SPACING

TYPE

POLE
NUMBER

PASS BAND
WIDTH

STOP BAND WIDTH

RIPPLE

dB

INSERTION
LOSS
dB
GUARANTEED
ATTENUATION
TERMINATING
IMPEDANCE
R1 //C1(W//pF)
OPERATING
TEMP.RANGE
0
c
CASE
dB kHz dB kHz dB kHz dB to ±kHz
21R15AZ 2 3 ±7.5 18 ±25 - - 0.5 1.5 35 +350~+1000
-200~ -1000
1.6K//2.5 -20~+70 UM-1
21R15BZ 4 3 ±7.5 40 ±25 - - 1.0 2.0 65 +350~+1000 -200~ -1000 1.6K//1.5 -20~+70 (UM-1)X2
21R15CZ 6 3 ±7.5 45 ±17.5 65 ±25 2.0 2.5 65 ±25~ ±300 1.6K//1.5 -20~+70 S-1*R-1
21R15DZ 8 3 ±7.5 65 ±17.5 90 ±25 2.0 3.0 90 ±25~ ±300 1.6K//1.5 -20~+70 S-2*R-2
21R15EZ 10 3 ±7.5 75 ±16.5 90 ±18 2.0 4.0 90 ±25~ ±300 1.6K//1.5 -20~+70 S-3*R-3

50 KHz CHANNEL SPACING

TYPE

POLE
NUMBER

PASS BAND
WIDTH

STOP BAND WIDTH

RIPPLE

dB

INSERTION
LOSS
dB
GUARANTEED
ATTENUATION
TERMINATING
IMPEDANCE
R1 //C1(W//pF)
OPERATING
TEMP.RANGE
0
c
CASE
dB kHz dB kHz dB kHz dB to ±kHz
21R30AZ 2 3 ±15 15 ±45 - - 0.5 1.5 35 +350~+1000
-200~ -1000
1.5K//0.5 -20~+70 UM-1
21R30BZ 4 3 ±15 40 ±50 - - 1.0 2.0 65 +350~+1000
-200~ -1000
2.0K//0.5 -20~+70 (UM-1)X2
21R30CZ 6 3 ±15 45 ±35 65 ±50 2.0 2.5 65 ±50~ ±300 2.2K//0.5 -20~+70 S-1*R-1
21R30DZ 8 3 ±15 65 ±35 80 ±50 2.0 3.0 80 ±50~ ±300 2.2K//0.5 -20~+70 S-2*R-2

See page 8 for 'R' case dimensions.